Kratke specifikacije
-
Hazardous area certifications
ATEX, CSA, IECEx
Područje primjene
The Raman Rxn-30 probe has cross-industry appeal for its robust gas-phase headspace monitoring, in situ measurements, and material compatibility. Certified for use in hazardous area environments, the Raman Rxn-30 probe can be inserted directly into processes with temperatures up to 150 degrees Celsius and pressures up to 68.9 barg (1,000 psig). It is available with a variety of mounting options for maximum installation and sampling flexibility.
Chemical: ammonia, methanol, HyCO, reaction monitoring, blending, catalysis
Polymer: polymerization reaction monitoring
Gas-phase streams in refining: hydrogen production and recycle fuel blending, fuel characterization
Power & Energy: IGCC power plants, gas turbines
Pharmaceutical: API reaction monitoring, drying
Food & Beverage: fermentations, offgas, volatiles
Prednosti
Reliable, quantitative gas-phase measurements
In situ measurement/no transfer lines or fast loops required
Can be directly inserted into processes with temperatures up to 150 °C and 68.9 barg (1,000 psig)
Industry standard installation options
Direct insertion, side insertion, or sample loop
Suitable for hazardous area/classified environments
Extended odabir
-
Vrhunski proizvodi
- Izuzetno funkcionalno i prikladno
Tehnička izvrsnost
Jednostavnost
-
Jednostavni proizvodi
- Jednostavno je odabrati, instalirati i rukovati
Tehnička izvrsnost
Jednostavnost
-
Standardni proizvodi
- Pouzdano, robustno i s malo održavanja
Tehnička izvrsnost
Jednostavnost
-
Specijalizirani proizvodi
- Dizajnirano za zahtjevne aplikacije
Tehnička izvrsnost
Jednostavnost
Promjenjivo
FLEX odabir | Tehnička izvrsnost | Jednostavnost |
---|---|---|
Fundamental odabir Udovoljite svojim osnovnim potrebama u mjernju |
Tehnička izvrsnost
|
Jednostavnost
|
Lean odabir Jednostavno upravljajte svojim osnovnim procesima |
Tehnička izvrsnost
|
Jednostavnost
|
Extended odabir Optimizirajte svoje procese s inovativnim tehnologijama |
Tehnička izvrsnost
|
Jednostavnost
|
Xpert odabir Ovladajte svojim najizazovnijim aplikacijama |
Tehnička izvrsnost
|
Jednostavnost
Promjenjivo |
Prethodnik
-
-
Tehničke informacije (TI)
Rxn-30 Raman Spectroscopic Probe Technical Information
System design and specifications for the Raman Rxn-30 probe
Jezik:
English
Verzije:
01/07/2022
Veličina datoteke:
569.9 KB
Naziv datoteke:
TI01632CEN_0222.pdf
-
-
-
Upute za uporabu (BA)
Rxn-30 Raman spectroscopic probe Operating Instructions
Commissioning, operation, and maintenance details
for the Raman Rxn-30 probeEN HR 28/06/2022Jezik:
English
Verzije:
28/06/2022
Veličina datoteke:
1.1 MB
Naziv datoteke:
BA02168CEN_0222.pdf
-
-
-
Kratke upute (KA)
Rxn-30 Raman Spectroscopic Probe Brief Operating Instructions
Quick start guide for the Raman Rxn-30 probe
Jezik:
English
Verzije:
01/07/2022
Veličina datoteke:
624.9 KB
Naziv datoteke:
KA01548CEN_0222.pdf
-
-
-
Ex sigurnosne upute (XA)
Rxn-30 Raman spectroscopic probe Safety Instructions
Hazardous area certifications and installation instructions
for the Raman Rxn-30 probeEN HR 21/06/202408/08/2023Jezik:
English
Verzije:
21/06/2024
Veličina datoteke:
1.3 MB
Naziv datoteke:
XA02748CEN_0424.pdf
-
-
-
PU (publikacija)
Raman Rxn5 analyzer - Laser-based composition analysis
An overview brochure about our Raman Rxn5 analyzer (including
the Raman Rxn-30 probe, the Rxn-40 probe, and the Rxn-41 probe),
a Raman spectroscopy analyzer system for gas phase measurements
powered by Kaiser Raman technology.Jezik:
English
Verzije:
28/10/2021
Veličina datoteke:
499.9 KB
Naziv datoteke:
PU01444CEN_0121.pdf
-
-
-
PU (publikacija)
Raman analyzer application guide for the oil & gas and chemical industries - Composition analysis of gas streams and LNG
A guide to our Raman spectroscopy analyzer and probe portfolio,
powered by Kaiser Raman technology, for composition analysis of
gas streams and LNG (includes the Raman Rxn4 analyzer, the
Raman Rxn5 analyzer, the Raman Rxn-30 probe, and
Raman Rxn-41 probe) in the chemical industry and oil & gas industry.Jezik:
English
Verzije:
08/12/2021
Veličina datoteke:
2.5 MB
Naziv datoteke:
PU01445CEN_0121.pdf
-
-
-
PU (publikacija)
石油・ガスおよび化学産業向け ラマン分光計アプリケーションガイド - ガスストリームおよびLNGの組成分析
化学産業および石油・ガス産業におけるガスストリームおよび LNG
の組成分析用(Raman Rxn4 アナライザー、Raman Rxn5 アナライザ
ー、Raman Rxn-30 プローブ、Raman Rxn-41 プローブを含む)、
Kaiser Raman テクノロジーによるラマン分光アナライザーおよび
プローブ製品ラインアップのご案内です。Jezik:
Japanese
Verzije:
13/05/2024
Veličina datoteke:
4.2 MB
Naziv datoteke:
PU01445CJA_0121_RamanAnalyzer_AppGuide_OilGas_ChemInd.pdf
-
-
-
PU (publikacija)
Industry standards on gas quality - Raman Rxn5 analyzer (syngas/LNG) andRaman Rxn4 analyzer (LNG)
A list of industry gas quality standards that our Raman Rxn5
analyzer meets for syngas / LNG and our Raman Rxn4
analyzer meets for LNG.Jezik:
English
Verzije:
20/04/2022
Veličina datoteke:
432.5 KB
Naziv datoteke:
PU01463CEN_0122.pdf
-
-
-
PU (publikacija)
Raman Rxn-30 probe - Gas phase analysis
An overview brochure about the Raman Rxn-30 probe, a
Raman spectroscopy probe for gas phase measurement
powered by Kaiser Raman technology in the Oil & Gas
industry and Chemical industry.Jezik:
English
Verzije:
20/01/2022
Veličina datoteke:
489.6 KB
Naziv datoteke:
PU01452CEN_0122.pdf
-
-
-
Inovacija (IN)
Mesure optique robuste de la composition chimique
-
Jezik:
French
Verzije:
16/03/2023
Veličina datoteke:
776 KB
Naziv datoteke:
IN01225CFR.pdf
-