Kratke specifikacije
-
Process temperature
max. 140°C
(284°F) -
Process pressure
max. 10bar
(145psi)
Područje primjene
The Unifit CPA442 process assembly is the simple solution for pH/ORP or oxygen measurement in tanks and pipelines of hygienic and sterile applications. Unifit is designed for inline cleaning and sterilization according to EHEDG and 3A criteria. You can be absolutely sure that your high-quality products are never contaminated but always completely safe.
Unifit CPA442 is intended for permanent installation in tanks and pipework in:
Food and beverage
Life sciences
Water treatment
Chemicals
It is suitable for use with pressures of up to 12 bar (stainless steel).
Prednosti
Certified hygienic design: Complies with 3A standard 74-05 and the criteria of EHEDG Class I
No contamination thanks to leak-tight, built-in electrode seal (molded seal)
Electropolished surface prevents build-up of residues (Ra=0.38 µm or 0.76 µm)
Suitable for CIP and SIP
Flexible adaptation to all applications by various hygienic process connections and flanges
Prethodnik
-
Jednostavni proizvodi
- Jednostavno je odabrati, instalirati i rukovati
Tehnička izvrsnost
Jednostavnost
-
Standardni proizvodi
- Pouzdano, robustno i s malo održavanja
Tehnička izvrsnost
Jednostavnost
-
Specijalizirani proizvodi
- Dizajnirano za zahtjevne aplikacije
Tehnička izvrsnost
Jednostavnost
Promjenjivo
FLEX odabir | Tehnička izvrsnost | Jednostavnost |
---|---|---|
Fundamental odabir Udovoljite svojim osnovnim potrebama u mjernju |
Tehnička izvrsnost
|
Jednostavnost
|
Lean odabir Jednostavno upravljajte svojim osnovnim procesima |
Tehnička izvrsnost
|
Jednostavnost
|
Extended odabir Optimizirajte svoje procese s inovativnim tehnologijama |
Tehnička izvrsnost
|
Jednostavnost
|
Xpert odabir Ovladajte svojim najizazovnijim aplikacijama |
Tehnička izvrsnost
|
Jednostavnost
Promjenjivo |
-
-
Tehničke informacije (TI)
Technical Information UniFit CPA 442
Process assembly
For safe installation of 12 mm sensors (Pg 13.5) in the food, beverage,
pharmaceitical and chemical industry.EN HR 23/01/201301/10/200401/08/2001Jezik:
English
Verzije:
23/01/2013
Veličina datoteke:
1.3 MB
Naziv datoteke:
TI00306CEN_1313.pdf
-
-
-
Upute za uporabu (BA)
Operating Instructions Unifit CPA442
Process assembly
For installation of 120 mm sensors in food industry, biotechnology and
chemical industryEN HR 29/05/2013Jezik:
English
Verzije:
29/05/2013
Veličina datoteke:
643.9 KB
Naziv datoteke:
BA01166CEN_0113.pdf
-
-
-
Područja djelatnosti (FA)
Jistota v analýze kapalin
Od senzorů po kompletní dodávku na klíč
Jezik:
Czech
Verzije:
12/01/2017
Veličina datoteke:
740.3 KB
Naziv datoteke:
Analyza_FA01018Ccs_0216.pdf
-
-
-
Područja djelatnosti (FA)
Esperti nell’analisi dei liquidi
Dai sensori singoli a soluzioni
complete “chiavi in mano”Jezik:
Italian
Verzije:
12/01/2017
Veličina datoteke:
3.9 MB
Naziv datoteke:
FA01018CIT_02.16.pdf
-
-
-
Područja djelatnosti (FA)
Catálogo Portfolio Analítica
Desde sensores hasta soluciones completas
Jezik:
Spanish
Verzije:
12/01/2017
Veličina datoteke:
1.5 MB
Naziv datoteke:
FA01018CES_Portfolio_Analitica_0216.pdf
-
-
-
Izjava proizvođača
Product family: UniFit H
Product root: CPA442-
Declaration number: HE_00679_02.17
Manufacturer specification: 1935/2004EN HR 01/09/2017Jezik:
English
Verzije:
01/09/2017
Veličina datoteke:
358.7 KB
Naziv datoteke:
HE_00679_02.17_CPA442.pdf
-
-
-
FDA deklaracija
Product family: UniFit H
Product root: CPA442-
Declaration number: FDA_00227_01.19
FDA specification: SealingEN HR 21/10/2019Jezik:
English
Verzije:
21/10/2019
Veličina datoteke:
276.2 KB
Naziv datoteke:
FDA_00227_01.19.pdf
-
-
-
FDA deklaracija
Product family: UniFit H
Product root: CPA442-
Declaration number: FDA_00335_01.24
FDA specification: SealingEN HR 13/02/2024Jezik:
English
Verzije:
13/02/2024
Veličina datoteke:
1.4 MB
Naziv datoteke:
FDA_00335_01.24.pdf
-
-
-
FDA deklaracija
Product family: UniFit H
Product root: CPA442-
Declaration number: FDA_00228_01.19
FDA specification: SealingEN HR 15/11/2019Jezik:
English
Verzije:
15/11/2019
Veličina datoteke:
275 KB
Naziv datoteke:
FDA_00228_01.19.pdf
-