Kratke specifikacije
-
Process temperature
-60°C...+280°C
(-76°F...+540°F) -
Process pressure / max. overpressure limit
Vacuum...100 bar
(1450 psi) -
Min. density of medium
Density from 0.4 g/cm3
(0.4 SGU)
Područje primjene
Liquiphant FTL81 is a point level switch for use in hazardous areas with all international certificates. FailSafe overfill protection in applications with functional safety up to SIL3 with one device. Reliable measurement values, not affected by: changing media properties, flow, turbulences, gas bubbles, foam, vibrations or build-up.
Point level switch for liquids up to SIL3.
Process connections: Threads and flanges
Temperature: -60 to +280°C (-76 to +540°F)
Pressure: -1 to +100bar (-14.5 to +1,450psi)
Sensor length: Extension pipe up to 3m (9.8ft)
Sensor material: 316L, Alloy C
International explosion protection certificates, overfill protection WHG, SIL, marine approvals
Prednosti
Use in safety systems requiring functional safety to SIL3 in accordance with IEC 61508 Ed.2.0/ IEC 61511-1/ISA 84-1 and DIN EN ISO 13849
Proof test: proof testing interval up to 12 years, Slave devices tested at the press of a button
Permanent self-monitoring/internal redundancy
4-20mA interface (acc. to NAMUR NE 06/NE 43): easy integration via the switching unit (Nivotester FailSafe FTL825) with a two-channel output (safety contacts) and locking function or direct integration into a safety PLC
No adjustment: quick, low-cost startup
No mechanically moving parts: no maintenance, no wear, long operating life
Monitoring of fork for damage, corrosion, build-up and mechanical blocking
Videozapisi
Xpert odabir
-
Specijalizirani proizvodi
- Dizajnirano za zahtjevne aplikacije
Tehnička izvrsnost
Jednostavnost
Promjenjivo
-
Jednostavni proizvodi
- Jednostavno je odabrati, instalirati i rukovati
Tehnička izvrsnost
Jednostavnost
-
Standardni proizvodi
- Pouzdano, robustno i s malo održavanja
Tehnička izvrsnost
Jednostavnost
-
Specijalizirani proizvodi
- Dizajnirano za zahtjevne aplikacije
Tehnička izvrsnost
Jednostavnost
Promjenjivo
FLEX odabir | Tehnička izvrsnost | Jednostavnost |
---|---|---|
Fundamental odabir Udovoljite svojim osnovnim potrebama u mjernju |
Tehnička izvrsnost
|
Jednostavnost
|
Lean odabir Jednostavno upravljajte svojim osnovnim procesima |
Tehnička izvrsnost
|
Jednostavnost
|
Extended odabir Optimizirajte svoje procese s inovativnim tehnologijama |
Tehnička izvrsnost
|
Jednostavnost
|
Xpert odabir Ovladajte svojim najizazovnijim aplikacijama |
Tehnička izvrsnost
|
Jednostavnost
Promjenjivo |
Prethodnik
-
-
Tehničke informacije (TI)
TI Weld-in adapter, process adapter and flanges
Level, pressure and temperature measurement
EN HR 25/03/202415/09/202328/10/202130/07/202119/06/2020Jezik:
English
Verzije:
25/03/2024
Veličina datoteke:
1.1 MB
Naziv datoteke:
TI00426FEN_2524.pdf
-
-
-
Tehničke informacije (TI)
Liquiphant FailSafe FTL80, FTL81, FTL85 Technical Information
Vibronic
Point level switch for liquidsEN HR 04/06/201316/07/2012Jezik:
English
Verzije:
04/06/2013
Veličina datoteke:
678.4 KB
Naziv datoteke:
TI01026FEN_0213.pdf
-
-
-
Upute za uporabu (BA)
Liquiphant FailSafe FTL80, FTL81, FTL85 Operating Instructions
Vibronic
Point level switch for liquidsEN HR 04/06/201316/07/2012Jezik:
English
Verzije:
04/06/2013
Veličina datoteke:
768.4 KB
Naziv datoteke:
BA01037FEN_0213.pdf
-
-
-
Kratke upute (KA)
Liquiphant M/S FTL51, FTL71, FTL81 Operating Instructions
High Pressure Sliding Sleeve
G 1, NPT 1EN HR 09/05/201731/07/201001/05/200801/10/2005Jezik:
English
Verzije:
09/05/2017
Veličina datoteke:
295.4 KB
Naziv datoteke:
KA00153FA6_1317.pdf
-
-
-
Kratke upute (KA)
Liquiphant M/S FTL51, FTL71, FTL81
High Pressure Sliding Sleeve
G 1 1/2, NPT 1 1/2EN HR 09/05/201731/07/201001/05/200813/10/2005Jezik:
English
Verzije:
09/05/2017
Veličina datoteke:
280 KB
Naziv datoteke:
KA00154FA6_1317.pdf
-
-
-
Kratke upute (KA)
Operating Instuction Liquiphant M FTL 51, FTL71, FTL81
Sliding Sleeve G 1 A, 1 NPT
for Unpressurised Operation.EN HR 09/05/201719/10/2005Jezik:
English
Verzije:
09/05/2017
Veličina datoteke:
158.9 KB
Naziv datoteke:
KA00151FA6_1317.pdf
-
-
-
Kratke upute (KA)
Operating Instuction Liquiphant FTL 51, FTL71, FTL81 Sliding Sleeve
Sliding Sleeve G 1½ A, 1½ NPT
for Unpressurised Operation.EN HR 09/05/201719/10/2005Jezik:
English
Verzije:
09/05/2017
Veličina datoteke:
141.4 KB
Naziv datoteke:
KA00152FA6_1317.pdf
-
-
-
Upute za ugradnju (EA)
Cover for housing T13 terminal compartment Installation instruction
Liquiphant M/S, Soliphant M, Liquicap M, Solicap M/S
EN HR 24/02/202215/08/201409/08/2012Jezik:
English
Verzije:
24/02/2022
Veličina datoteke:
119 KB
Naziv datoteke:
EA01050FA2_0322.pdf
-
-
-
Upute za ugradnju (EA)
Cover for housing T13 electronic compartment Installation instruction
Liquiphant M/S, Soliphant M, Liquicap M, Solicap M/S
EN HR 11/08/201409/08/2012Jezik:
English
Verzije:
11/08/2014
Veličina datoteke:
164.3 KB
Naziv datoteke:
EA01048FA2_0214.pdf
-
-
-
Upute za ugradnju (EA)
Cover for housing F13 Installation instruction
Liquiphant M/S, SoliphantM, Liquicap M, Solicap M/S
EN HR 11/08/201409/08/2012Jezik:
English
Verzije:
11/08/2014
Veličina datoteke:
134.4 KB
Naziv datoteke:
EA01046FA2_0214.pdf
-